Direct Outdoor Thermal Enclosures · NEMA 250 / IEC 60529 IP55–IP65 · 15-Minute Formal Quote
MODEL CODE OD-42U-AC4000SERIES High-Density Edge ComputeCATEGORY Solar BESS & Mining

OD-42U-AC4000 — 42U Full-Height Outdoor Edge-Compute Cabinet with 4000W Industrial AC

When remote industrial sites need full 42U data-center rack depth and 3.0–3.5 kW of active IT cooling without constructing a brick-and-mortar equipment shelter.

Request 15-Minute Formal Quote WhatsApp +86 13392250172Email jacklau@outdoornetworkenclosure.com

Dual-Unit Technical Specifications (OD-42U-AC4000)

ParameterEngineering SpecificationReference / Notes
External Dimensions (H × W × D)2250 × 800 × 1100 mm (88.6 × 31.5 × 43.3 in)1200 mm (47.2 in) ultra-deep option for dual-PSU GPU servers
Usable 19" Rack Envelope42U · 900 mm (35.4 in) usable rail depth2.0 mm 4-post EIA-310-E rails; 800 kg (1,763 lb) static load capacity
Closed-Loop Cooling Capacity4,000 W (13,648 BTU/hr) @ L35/L35Single 4000W or redundant dual 2 × 2000W lead/lag AC configuration
AC Input Voltage220–240V / 50–60Hz single-phase or 380–415V 3-phase optionIncludes surge suppression, circuit breakers, and phase monitor
Double-Wall Solar Shield25 mm (1.0 in) ventilated 4-side + insulated double roof25 mm closed-cell thermal liner + RAL 7035 UV polyester coat
Enclosure Shell Material2.0 mm welded galvanized steel frame + 1.5 mm double-wall panelsOptional 304/316L stainless steel for corrosive industrial pads
Battery & UPS ZoneSupports 3U–12U rackmount online UPS + external battery bayingMulti-bay side-by-side ganging available for power + IT split
Ambient Operating Range-40 °C to +55 °C (-40 °F to +131 °F) with optional 1500W heaterModbus RTU / SNMP environmental alarm & remote telemetry ready
Standards AlignmentNEMA 250 / IEC 60529 IP55–IP65 & EIA-310-EBuilt to standard; thermal test sheets available per project

Target Applications & Operating Fit

  • Outdoor micro-data-center deployments running standard 2U/4U enterprise servers, hyperconverged nodes, or edge AI GPUs
  • Private 5G core and macro-RAN base stations in open-pit mines, ports, rail yards, and oil/gas refineries
  • Large utility solar + BESS collector substations consolidating SCADA, EMS, historian servers, and cybersecurity appliances
  • Sites avoiding the permitting, civil construction, and lead time of concrete equipment shelters

Structural & Standards Engineering

  • 4000W (13,648 BTU/hr) high-capacity closed-loop cooling handles up to 3.2–3.5 kW of continuous server heat load even under full summer sun.
  • Available with redundant 2 × 2000W dual-AC lead/lag controls so a single compressor fault never causes thermal shutdown.
  • 1100 mm standard depth (1200 mm option) accommodates full-length sliding server rails, vertical 0U PDUs, and rear cable arms.
  • Heavy welded steel base frame with crane lifting eyes and seismic floor-anchor gussets supports 800 kg (1,763 lb) static load.

5-Parameter Engineering Modification Scope

  • Redundant 2 × 2000W closed-loop AC units with automatic lead/lag rotation and failover relay
  • Dual-bay ganged cabinet assembly (42U IT bay + dedicated 42U UPS/LiFePO4 battery bay)
  • Integrated automatic fire suppression tube, water-leak rope sensor, smoke detector, and SNMP gateway
  • 1200 mm (47.2 in) deep chassis with vertical 0U metered PDUs and front-to-back airflow blanking panels
  • 316L stainless-steel coastal/petrochemical exterior cladding with coated condenser coils

Technical FAQs

Can the OD-42U-AC4000 be ordered with redundant dual air conditioners?

Yes. For zero-downtime edge compute or private 5G sites, we configure two door- or side-mounted 2000W closed-loop units with an alternating lead/lag controller so both share wear and automatically ramp to full output if one unit requires service.

Why is 220–240V required instead of 110V on a 4000W enclosure AC?

A 4000W cooling unit draws roughly 1.4–1.8 kW of electrical input power plus startup inrush, plus any optional winter heater. Operating at 220–240V (or 380–415V 3-phase) cuts line current in half and aligns with standard 208V/240V enterprise server PDUs.

Can standard 19-inch data-center servers on sliding rails mount directly inside?

Yes. Four-post 2.0 mm square-hole EIA-310-E rails with 900 mm usable depth (or 1000 mm in the 1200D option) accept standard Dell, HPE, Supermicro, and Cisco sliding rail kits without adapters.

How are 42U outdoor cabinets shipped and offloaded at remote pads?

Units ship upright on heavy-duty reinforced pallets or export wooden crates with integrated top crane lifting lugs and bottom forklift pockets in the plinth base.

OD-12U-AC300

12U Pole/Pad Mount + 300W Micro-AC

Compact 12U double-wall solar-shielded cabinet pairing a 300W (1,024 BTU/hr) closed-loop compressor AC with heavy-duty pole/wall/pad brackets for WISP relays and campus fiber nodes.

View Datasheet →
OD-24U-AC600

24U Double-Wall + 600W AC

Balanced 24U pad-mount double-wall cabinet combining a 600W (2,047 BTU/hr) closed-loop air conditioner with a segregated lower 48V battery bay for WISP distribution hubs and roadside ITS.

View Datasheet →
OD-32U-AC2000

Flagship 32U Double-Wall + 2000W Industrial AC

Flagship 32U double-wall solar-shielded enclosure pairing a high-ambient 2000W (6,824 BTU/hr) closed-loop industrial AC with full-depth 19-inch rails for dense ITS, solar-BESS, and mining edge compute.

View Datasheet →